Now 4138 visitors
Today:0 Yesterday:0
Total: 141619
215S 51P 5R
2026-10-21, Week 43 |
| Member Login |
| TACT Journal Homepage |
| Call for Paper |
| Committee |
| Find My Paper |
| Author Homepage |
| Statistics & History |
| Welcome Message |
| Paper Procedure |
| FAQ |
| Paper Archives |
| Outstanding Papers |
| Author Homepage |
| - Paper Procedure |
| - Journal Procedure |
| - Presentation Tips |
|
| Program & Proceedings |
| Program with Papers |
| Plenary Session |
| Tutorial Session |
|
| Presentation Platform |
| Hotel & Travel Info |
| About Korea |
| Accommodation |
| Transportation |
| VISA |
| Other Infomation |
|
| Photo Gallery |
| Scheduler Login |
| Seminar |
| Archives Login |
|
| Sponsors |

|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Save Q&A |
|
* Edit or answer any Q&A by selecting Q&A number Hyper Link below + Write button (Save) |
ICACT20220141 Question.1 Questioner: tomayoon@ieee.org 2022-02-15 ¿ÀÈÄ 12:49:43 |
ICACT20220141 Answer.1 Answer by Auhor liumengup@126.com 2022-02-15 ¿ÀÈÄ 12:49:43
Chrome Click!! |
| First of all, thank you for the good research paper and presentation contents. I would like to know more about the research environment used in this study, and also in detail about the equipment & operating systems, development languages and software libraries you used. |
Thanks for your attention. The equipment consists of a 35kV oil-immersed transformer, an implanted fault source, and an external controllable voltage regulating device. A variety of fault sources can be switched flexibly, and the 35kV transformer can be powered through the console, which can stimulate the fault source to produce a fault.
transformer
Dimensions: 1900¡¿1645¡¿2000 (length¡¿width¡¿height)
Total weight (including oil): 2380kg
Oil weight: 1100kg
Rated voltage:
HV, three-phase AC35kV
LV1, three-phase AC400V
LV2 (excitation), three-phase AC400V
Rated capacity: 50kVA;
Cooling method: ONAF (with fan)
The software languages is used pathon, and the libraries is cuda supported from Invida. |
ICACT20220141 Question.2 Questioner: tomayoon@ieee.org 2022-02-15 ¿ÀÈÄ 12:56:00 |
ICACT20220141 Answer.2 Answer by Auhor liumengup@126.com 2022-02-15 ¿ÀÈÄ 12:56:00
Chrome Click!! |
| Will you tell us what is the major achievement of this paper, and also what is further study issue from this? Thanks in advance!! |
This paper obtained better recognition results than the other two papers, and then more accurate transformer high-frequency partial discharge detection can be achieved. The next step is to update the network model, studing a more complex model, to improve the recognition accuracy, or add other Transformer state quantity, to improve equipment state evaluation level. |
ICACT20220141 Question.3 Questioner: namacabale@gmail.com 2022-02-16 ¿ÀÈÄ 8:47:07 |
ICACT20220141 Answer.3 Answer by Auhor liumengup@126.com 2022-02-16 ¿ÀÈÄ 8:47:07
Chrome Click!! |
| Dear Author, you have a very good research. Is there an existing technology almost similar to your proposal that has been deployed in real world environment? What does it lack that your work specifically addressed? Thank you and stay safe.
|
Thanks for your questions. This research is supported by state grid shandong electric coorperation, this method will deploy in the analsis of transformations in shandong China. The result use de-noise algorithm and CNN, and get more accurate result than 2 papers as shown in papers, and in the next steps, we will add more information to get more accurate result. |
| |