IEEE/ICACT20210158 Question.1
Questioner: baekj@wssu.edu    2021-02-08 ¿ÀÈÄ 2:05:05
IEEE/ICACT20210158 Answer.1
Answer by Auhor charnon2002@hotmail.com   2021-02-08 ¿ÀÈÄ 2:05:05
Charnon. I enjoyed seeing your interesting research and presentation. According to your results, the 2D errors (especially for Min. 2D error) sometimes did not show the linear improvement as you increase the length of the observing sessions. When length is set to 15min, 30min, and 60min, Min.2D error is 3.8, 11.5, and 2.4, respectively. Would you tell me what can be a reason for this inconsistency? The observation error value depends on the sky weather conditions during the experiment. In slide 20, We count the number of 2D Errors less than 1 meter and 50cm compared with a total number of experimental in order to represent the confidence level of data.