IEEE/ICACT20210172 Question.2
Questioner: mihai.sima@ieee.org    2021-02-10 ¿ÀÈÄ 2:47:24
IEEE/ICACT20210172 Answer.2
Answer by Auhor tetsuya-iye@kke.co.jp   2021-02-10 ¿ÀÈÄ 2:47:24
For some reason, my question was deleted. My question refers to Slide #12. You mention that the calibration *method* over the entire bandwidth would be a further study. But are you positive that calibration can give you the required accuracy over the entire bandwidth? Otherwise, there would be no point in generating a calibration method. Thank you. Thank you for your question. Yes, I am positive that the calibration can give us the required accuracy over the entire bandwidth. At least, for the MEP method, we could obtain the frequency dependence of the offset values of phase and gain. Based on these results, we can make calibration value table for the entire bandwidth, although the calibration value set is determined only at 28 GHz in this work.